AC Current Capacity:
Input - 16 Amp capacity required
Output - 8 - 16 Amps RMS * (maximum, all outlets combined - continous)
Linear Noise Attenuation:
Tranverse (Differential) Mode:
> 40 dB from 10 kHz - 100 kHz, > 80 dB from 100 kHz - 1GHz
(Linear attenuation curve from 0.05 - 100 ohms line impedance)
Common Mode (video outlets):
> 75 dB, 10 Hz - 50 kHz, > 40 dB 50 kHz - 1 MHz
Outlets:
8 (symmetrical balanced outlets)
4 (Power Factor Technology outlets - 9 amps RMS reserve - reactive load - over 80 amps pk. charge, 3x 10A, 1x 16A)
Transient Voltage Surge Suppression:
230 VAC - Series Multi-Stage Protection - Non-Sacrificial with Zero Ground Contamination.
(376 V peak clamping & 6000V / 3000A input)
Extreme Voltage Shutdown (275VAC ±5VAC VAC)
Telco Cable / Satellite (less than .1dB insertion loss)
Dimensions: 152mm H x 432mm W x 413mm D
(Standard 3 rack unit height without feet)
Weight: 40 kg.
Power Consumption: 8.5 Watts for display and control circuits independant of actual load
Safety Agency Listing: C-ETL